Sign in

Sign up

Gilbarco Sk700 Programming Manual May 2026

To develop or program a feature on a Gilbarco SK700 dispenser, you must access the programming mode through the manager keypad using specific security codes. Accessing Programming Mode

Most "features" or configuration settings are reached by entering the Manager Functions Initialize : Press the key on the manager keypad. Security Code : Enter the master security code, typically , then press Command Input

: The unit enters function mode (often indicated by a "0" on the display), allowing you to input specific Function Codes Common Programming Features & Function Codes

The following codes are used to configure or "develop" specific dispenser behaviors: Kentronics PPU (Price Per Unit) Settings : Used to set or change fuel prices directly at the pump. Maximum Allocation

: Set limits on the maximum volume or amount a customer can dispense in one transaction. Pulse Channel Configuration Function Code 9 : Set the start position of pulse channels (High or Low). Function Code 10

: Set the pulse format (e.g., Channel B lags Channel A by 90°). Communication Timeout Code 40.22

to adjust the PPU communications timeout (default is 10 seconds, often increased to 30 seconds for specific setups). Country Code

allows you to set the country (e.g., "36" for Australia), which automatically loads regional default configurations. This can typically only be done after a Cold Start Kentronics Advanced Feature Deployment

For more complex feature integration, such as multimedia or payment systems: USB Configuration

: On Apollo CPU boards, a special USB stick can be used to "Get Config" (Code 8) or "Send New Software" to the pump while in CRIND (Card Reader in Dispenser) : Advanced features like Gilbarco FlexPay™ Applause™ Media System

require a separate diagnostic startup menu accessed via the FlexPay EPP. Note on Safety

: Any procedure requiring internal electronics access necessitates a total electrical shut-off to the unit to prevent fire or explosion. specific feature Gilbarco Sk700 Programming Manual

(e.g., price changes, pulse settings, or communication protocols) are you trying to configure or develop for the SK700? Programming SK700/SK700-2 Gilbarco | PDF - Scribd

Programming the Gilbarco SK700 and SK700-II involves using a manager keypad to enter security codes, typically 0128, to configure parameters like unit prices, pump numbers, and communication settings. A "Cold Start" procedure, which requires manipulating physical jumpers on the processor board, is necessary to reinitialize the unit and set core configurations. Detailed programming, installation, and parts manuals can be found at Scribd and Kentronics. Programming SK700/SK700-2 Gilbarco | PDF - Scribd

Set Real time Volume – Function Code 5. 40.5 -> 1 Real time Money. 40.5 -> 2 Real time Volume. 25-02.09E_ENGLISCH.DOC 30.05.2008 - Scribd

Programming the Gilbarco SK700 and SK700-II dispensers involves using a manager’s keypad for basic setup parameters, such as pump type, protocol, and pricing, following a necessary "Cold Start" procedure to clear memory. Key technical procedures, including CAL switch positioning and USB configuration, are outlined in official documentation, such as the Gilbarco Installation & Commissioning Manual. For comprehensive technical instructions, reference the Kentronics SK700-2 Cold Start Guide.

Gilbarco Sk700 Programming Manual: A Comprehensive Guide

The Gilbarco SK700 is a popular point-of-sale (POS) system used in various retail fueling applications, including gas stations and convenience stores. The system is designed to manage fuel sales, inventory, and customer transactions efficiently. However, to get the most out of the SK700, it's essential to understand its programming and configuration. This article provides an in-depth look at the Gilbarco SK700 programming manual, covering its key features, setup, and troubleshooting.

Overview of the Gilbarco SK700

The Gilbarco SK700 is a versatile POS system that offers a range of features to streamline fuel sales, inventory management, and customer transactions. Some of its key features include:

  • Fuel Sales Management: The SK700 allows you to manage fuel sales, track inventory, and monitor fuel prices.
  • Inventory Management: The system enables you to track inventory levels, manage stock levels, and automate inventory reporting.
  • Customer Transactions: The SK700 supports various payment methods, including credit/debit cards, cash, and loyalty programs.
  • Reporting and Analytics: The system provides real-time reporting and analytics to help you make informed business decisions.

Gilbarco SK700 Programming Manual: Importance and Purpose

The Gilbarco SK700 programming manual is a critical resource for system administrators, technicians, and users who need to configure and maintain the POS system. The manual provides detailed instructions on how to:

  • Configure system settings: Adjust system parameters, such as date and time, currency, and tax rates.
  • Set up fuel sales: Configure fuel types, prices, and sales settings.
  • Manage inventory: Set up inventory tracking, stock levels, and reporting.
  • Integrate payment methods: Configure payment gateways, loyalty programs, and credit/debit card settings.

Key Components of the Gilbarco SK700 Programming Manual To develop or program a feature on a

The Gilbarco SK700 programming manual covers various aspects of system configuration and maintenance. Some of the key components include:

  • System Setup: This section provides step-by-step instructions on how to set up the SK700 system, including configuring system settings, setting up fuel sales, and managing inventory.
  • Fuel Sales Configuration: This section explains how to configure fuel sales settings, including setting up fuel types, prices, and sales settings.
  • Inventory Management: This section provides guidance on how to set up inventory tracking, stock levels, and reporting.
  • Payment Method Configuration: This section explains how to integrate payment gateways, loyalty programs, and credit/debit card settings.

Step-by-Step Guide to Programming the Gilbarco SK700

Programming the Gilbarco SK700 requires a thorough understanding of the system's configuration and settings. Here's a step-by-step guide to help you get started:

  1. Accessing the Programming Menu: To access the programming menu, press the "Prog" key on the SK700 keypad and enter the programming password.
  2. Configuring System Settings: Navigate to the "System Setup" menu and configure system settings, such as date and time, currency, and tax rates.
  3. Setting up Fuel Sales: Navigate to the "Fuel Sales Configuration" menu and set up fuel types, prices, and sales settings.
  4. Managing Inventory: Navigate to the "Inventory Management" menu and set up inventory tracking, stock levels, and reporting.
  5. Integrating Payment Methods: Navigate to the "Payment Method Configuration" menu and integrate payment gateways, loyalty programs, and credit/debit card settings.

Troubleshooting Common Issues

While the Gilbarco SK700 is a reliable POS system, users may encounter issues during programming or operation. Here are some common issues and troubleshooting tips:

  • Error Messages: If you encounter error messages during programming, refer to the troubleshooting section in the manual or contact Gilbarco technical support.
  • Fuel Sales Issues: If you experience issues with fuel sales, check the fuel sales configuration and ensure that fuel types, prices, and sales settings are correctly set up.
  • Inventory Discrepancies: If you notice inventory discrepancies, check the inventory management settings and ensure that inventory tracking, stock levels, and reporting are correctly configured.

Conclusion

The Gilbarco SK700 programming manual is a comprehensive resource for system administrators, technicians, and users who need to configure and maintain the POS system. By understanding the system's configuration and settings, you can optimize fuel sales, inventory management, and customer transactions. This article provides a detailed guide to the Gilbarco SK700 programming manual, covering its key features, setup, and troubleshooting. Whether you're a new user or an experienced technician, this article aims to provide valuable insights and practical guidance to help you get the most out of your Gilbarco SK700 system.

Gilbarco SK700 programming instructions are typically found within the Manager Functions Manual

or specialized service guides. Programming is generally performed using a Manager Keypad

and often requires specific security codes depending on the access level required. Core Programming Codes & Access

To enter programming mode, you typically use the following master codes on the keypad: Master Code: (frequently used for Function mode/Level 4 commands). Level 2 Security Code: (used for standard parameters like pump numbers). Key Function Codes Fuel Sales Management : The SK700 allows you

Programming is organized by function codes. Common configurations include: Pump Numbers: Command Code 40 in Level 2. Real-Time Volume/Money:

Function Code 5 (40.5 -> 1 for Money, 40.5 -> 2 for Volume). Pulse Scaling: Function Code 6 (e.g., 40.6 -> 100 for 100 Pulses/Liter). Auto Authorization: Function Code 8 (40.8 -> 1 to Enable). Slowdown Valve Settings: Command Code 88 (e.g., 88.1.1 for Side 1 Grade 1). Cold Start Procedure

A "Cold Start" is required for major configuration changes, such as changing the Country Code Preparation: Power down the unit and move the CAL switch to the "CAL" position.

Move the two-wire enable jumper to the "Cold Start" position. The display should flash , enter code , and then press to reboot. Re-Configure:

After the reboot, basic parameters like Country Code, Pump Type, and Protocol must be set. Reference Manuals Installation & Commissioning Manual: Available at Gilbarco Australia , covering setup and initial codes. Programming Guides:

Summarized versions of parameter sets are often hosted on platforms like Technical Overview: Details on electronics and hydraulics can be found in the SK700 Technical Overview or trying to resolve a particular error code on your dispenser?

Gilbarco SK700 dispensers use a command-code system for programming, typically accessed via a manager keypad. Programming requires specific security PINs depending on the level of access needed. General Programming Steps Access Manager Mode : Press the key on the manager keypad. Enter Security PIN Level 1 (Basic/Manager) : Default is Level 2 (Service) : Default is Level 4 (Technician/Engineer) : Default is Enter Command Code

: Input the specific code for the parameter you wish to change (e.g., for unit price). Confirm and Exit to save changes and to return to normal operation. Kentronics Common Command Codes The following codes are frequently used for configuration: Set Price Per Unit (PPU) : Command Code (Level 1). Set Pump Number (ID) : Command Code (Level 2). Operations Mode (Two-Wire/Standalone) : Command Code (Level 1). Special Operations (Soft Cold Start/Reboot) : Command Code (Level 2). Volume Pulse Scale : Command Code (Level 4). Cold Start Procedure

A "Cold Start" is required after major repairs or board replacements to reset parameters to defaults. Kentronics Hardware Prep : Power down the pump. Move the switch to the "CAL" position and move the Cold Start link/jumper to the "Cold Start" position on the CPU board. Initialization : Power up the unit. A flashing

should appear on the display, indicating the system is in cold start mode. Basic Setup , enter the master code , and configure the country code (e.g., Code ) before moving the jumper back to its original position. Kentronics

4. Network & Communications

  • Configure communication parameters to host, POS, or forecourt controllers:
    • Protocol: TCP/IP or serial (RS-232/RS-485) depending on host.
    • IP Settings: IP address, subnet mask, gateway (for TCP/IP).
    • Port: TCP port number matching host.
    • Serial Settings: Baud rate, parity, data bits, stop bits, and device ID.
  • Set retry intervals, timeouts, and enable/disable automatic reconnect.
  • For secure sites, set VPN or secure tunneling as required by site network policies.

2. Accessing Programming Mode

  • Enter installer/technician mode using the dispenser’s keypad and/or authorized key switch per site configuration.
  • Typical steps:
    1. Turn key switch to PROGRAM or TECH position.
    2. On keypad, press function sequence (e.g., 1-2-3 or MENU + PIN) as set by site.
  • If a PIN is required, obtain from site administrator; default PINs are often changed for security.

Additional Tips

  • Make sure you have the correct version of the manual for your specific SK700 system, as updates and revisions may have been made.
  • If you're new to programming fuel dispensers, consider consulting with a professional or taking training courses to ensure you're using the system correctly and safely.

1. Safety & Preparations

  • Power off the dispenser before opening panels.
  • Use ESD precautions when handling boards.
  • Have the dispenser serial number, firmware version, and site schematic available.
  • Ensure authorized access and appropriate permits for fuel equipment work.