It seems you're asking about an interesting feature of the GP-4402WW software.
The GP-4402WW is a model of Pro-face Human-Machine Interface (HMI). Its software ecosystem is primarily GP-Pro EX for project development, plus Transfer Tool and Logic Navigator (for optional ladder logic).

Here’s one particularly interesting feature related to its software:

Conclusion

The GP-4402WW software ecosystem is anchored by Pro-face GP-Pro EX, a robust and mature development environment. Whether you are installing USB drivers for the first transfer, configuring an Ethernet/IP driver to talk to a ControlLogix PLC, or performing a critical firmware update, understanding these software tools is essential for system integrators and maintenance technicians.

By following the installation steps, driver configurations, and troubleshooting tips outlined above, you will ensure that your GP-4402WW operates reliably for years. Always keep your GP-Pro EX version up to date, use genuine software licenses, and never skip the simulation step before going live.

For further support, consult the official GP-4402WW Hardware Manual and the GP-Pro EX Reference Guide available on the Pro-face website.


Keywords used: GP-4402WW software, Pro-face GP-Pro EX, GP-4402WW driver, HMI programming, Pro-face update manager, PLC communication software.

The GP-4402WW is a 7-inch widescreen HMI from Pro-face’s GP4000E series. To program and manage this device, you must use the GP-Pro EX software. While modern versions of the software support this model, users often encounter issues where the model name does not appear in the selection menu, requiring specific patches or installation steps. Core Software: GP-Pro EX

GP-Pro EX is the premier development software for Pro-face HMIs, offering a unified platform for screen design and logic programming.

Version Compatibility: The GP-4402WW is officially supported from GP-Pro EX Version 4.04 and later.

Key Features: It allows for recipe management, alarm logging, and integrated energy monitoring. It also supports internal logic programming (ladder diagrams), which can help reduce the processing load on your PLC.

Virtual Testing: For those without physical hardware, the software includes WinGP, which can act as a virtual HMI on a PC for up to three hours at a time for testing and verification. Enabling the GP-4402WW Model

A common issue for engineers is that the GP-4402WW (or its companion GP-4502WW) remains hidden even in newer software versions like 4.07 or 4.09. To fix this, you must run a specific model-addition patch found in your installation folder:

Close GP-Pro EX: The patch will not work if the software is running.

Locate the Patch: Navigate to your installation directory (typically C:\Program Files (x86)\Proface\GP-Pro EX 4.0\OP\).

Run Installer Files: Double-click YTSetup.exe and YTPartsLCSetup.exe.

Note: These may be hidden files, so ensure your Windows Explorer settings are set to "Show hidden files and folders". gp-4402ww software

Restart Software: Once these brief background processes finish, the GP-4402WW model should appear under the GP4000E series in the device selection menu.

The GP-4402WW is a 7-inch widescreen Human Machine Interface (HMI) from the Pro-face GP4000E series. Efficiently operating and programming this hardware requires specialized software—specifically GP-Pro EX—and proper system configuration to handle the unit's unique specifications. Primary Programming Software: GP-Pro EX

The primary environment for developing, screen-designing, and logic-programming for the is GP-Pro EX. Version Compatibility: The

is officially supported starting from GP-Pro EX Version 4.03.400 or later. Using versions earlier than this may result in the model not appearing in the selection menu.

Core Capabilities: The software allows users to create visual interfaces with 65,536 colors and features "ready-made" functions to reduce development time.

Transfer Utilities: Included within GP-Pro EX is a transfer tool used to "receive" (upload) or "send" (download) project files to the HMI via USB or Ethernet. Software Configuration and Model Activation A common technical hurdle for users is that the

may not be visible in the model selection list even in compatible software versions like 4.08 or 4.09. This is often resolved by running a specific configuration patch found within the installation directory:

is a 7-inch wide screen Human Machine Interface (HMI) part of the GP4000E Series Pro-face (Schneider Electric)

. It is designed as a budget-friendly, high-performance touch panel for industrial automation. Essential Software: GP-Pro EX To program and configure the GP-4402WW, you must use Version Requirement : The GP-4402WW is specifically supported from GP-Pro EX version 4.03.400 or later Model Selection Fix

: If you cannot find the GP-4402WW in your model selection list, you may need to run specific patch files located in your installation directory: Navigate to C:\Program Files(x86)\Proface\GP-Pro EX4.0x\OP YTSetup.exe YTPartsLCSetup.exe while GP-Pro EX is closed. Key Technical Specifications

The GP-4402WW features a robust set of hardware capabilities suitable for various factory floor applications: : 7" Wide TFT Color LCD with 65,536 colors.

: 32 MB Flash EPROM for application storage and 128 KB for backup memory. Interfaces : RS-232C (D-Sub 9-pin). : RS-422/485 (D-Sub 9-pin). : 1x Type A (Host) and 1x Mini-B (Device). : IEEE802.3i/IEEE802.3u (10BASE-T/100BASE-TX). Functional Limitations

While part of the advanced GP4000 family, the "WW" (Economy) model has specific limitations compared to standard units: Touch Points : Does not support 2-point multi-touch. Volatile Variables

: Logic program variables are volatile; they initialize to zero/off when the unit is power-cycled, even if "Retentive" is selected. Remote Access : Does not support the Pro-face Remote HMI app. Multimedia : Does not support the Sub Display's Movie Player. Getting Started Resources : Access the GP-4402WW Hardware Manual for wiring and installation details. : For beginners, Pro-face Basic Training videos

The GP-4402WW is a 7.5-inch widescreen HMI from Pro-face’s GP4000E series. To program or configure this device, you must use the GP-Pro EX software. 1. Required Software & Compatibility It seems you're asking about an interesting feature

The GP-4402WW requires a specific version range of the GP-Pro EX editor to function correctly:

Minimum Version: Supported from GP-Pro EX Ver. 4.03.400 or later.

Recommended Versions: Versions like V4.06.200 or V4.09 are commonly used for this model.

Activation Patch: In some cases, even with Ver. 4.09, the model may not appear in the selection list. You may need to run a hidden patch located at: C:\Program Files (x86)\Pro-face\GP-Pro EX 4.09\OP\YTSetup.exe to enable the GP4000E models. 2. How to Obtain the Software

You can download the software directly from the Pro-face Support / Downloads page.

Pro-face GP-4402WW (part of the GP4000E series) is a 7-inch widescreen HMI by Schneider Electric that primarily utilizes the

software suite for screen editing and communication configuration Pro-face by Schneider Electric Core Software: GP-Pro EX The standard software used to program this unit is

, a versatile development environment for creating HMI and PLC projects. Pro-face by Schneider Electric Version Compatibility : The GP-4402WW is supported starting from GP-Pro EX Ver. 4.03.400 Essential Model Enablement

: In many versions of GP-Pro EX (including 4.09), the GP-4402WW model may not be visible in the initial project selection. To enable it, you must run a specific hidden patch file while the software is closed: C:\Program Files (x86)\Pro-face\GP-Pro EX 4.0x\OP\ Files to Run YTSetup.exe YTPartsLCSetup.exe Requirement

: You may need to enable "Show hidden files" in Windows Explorer to see these files. Schneider Electric Software Features & Capabilities Driver Support

: The software allows the GP-4402WW to communicate via multiple protocols, including MODBUS TCP, CANopen Slave, and various PLC-specific drivers. Virtual Backup Memory

: Since the GP-4402WW lacks physical SRAM (backup memory), the software manages a "virtual backup memory" area within the unit's internal FLASH EPROM to store alarm history and filing data. Migration Support GP-Pro EX Ver. 5.01 includes tools like the Project Converter

to migrate older projects from GP-PRO/PBIII C-Package to the newer environment. Pro-face by Schneider Electric Technical Resources & Downloads

For official drivers, manuals, and software updates, you can use the Pro-face GP4000E Support Page

The Go to product viewer dialog for this item. is a key entry-level Human Machine Interface (HMI) in the Pro-face GP4000E series. To program and manage this device effectively, you must use Pro-face's dedicated software ecosystem, primarily GP-Pro EX. Error 1: "The project was created with a

Below is a detailed guide on the software requirements, features, and setup steps for the Core Programming Software: GP-Pro EX The primary software used to develop projects for the is GP-Pro EX.

Version Compatibility: While newer versions are generally recommended, the

model specifically requires GP-Pro EX version 4.03 or later. Key Features:

Intuitive Interface: Includes 3D simulation components and a vast library of sample images to reduce development time.

Debugging Tools: Allows users to debug ladder programs and adjust PLC data directly through the HMI.

Data Handling: Supports CSV data conversion and historical trend graphing for production monitoring.

Connectivity: Equipped with drivers for a wide range of control equipment, including MODBUS TCP, CANopen Slave, and various PLC protocols. Essential Setup: Activating Support

A common issue for users is that the GP-4402WW model may not appear in the model selection menu even if the software is version 4.03 or higher. To fix this, you must run a specific background installer included with the software: Close the GP-Pro EX application.

Navigate to the installation folder (typically C:\Program Files (x86)\Proface\GP-Pro EX 4.0x\OP). Run YTSetup.exe and YTPartsLCSetup.exe.

: These may be hidden files; ensure your Windows Explorer settings are set to "Show hidden files and folders". Restart GP-Pro EX. The should now be selectable under the "GP4000E Series". GP Pro EX "GP4402WW" Show Model Mar 6, 2022 YouTube·plc247 Automation GP-Pro EX - Operation Management for HMI - Proface

Based on the model number GP-4402WW, you are referring to a White Rodgers 50E47-843 Universal Hot Surface Igniter. This is a popular HVAC replacement part used to ignite gas furnaces.

Here is a comprehensive review of the product, broken down by performance, installation, and value.


Error 1: "The project was created with a newer version of GP-Pro EX."

Cause: Your HMI has older firmware or you are using an older copy of GP-Pro EX. Fix: Update your GP-Pro EX software to the latest version (e.g., V4.09 or higher) or perform a System Program update on the HMI.

Steps to Install the GP-4402WW USB Driver:

  1. Download the driver: Located inside the GP-Pro EX installation folder (C:\Proface\GP-Pro EX\UsbDriver) or on the Pro-face support site under "GP-4402WW Downloads."
  2. Power the HMI: The GP-4402WW must be powered on (24 VDC) before connecting the USB cable. It cannot be bus-powered.
  3. Connect the cable: Plug USB Mini-B into the "Transfer" port on the rear of the GP-4402WW.
  4. Manual driver selection: When the "Found New Hardware" wizard appears, point it to the USBMON.INF file from the driver folder.
  5. Verify installation: Open Windows Device Manager. You should see "Pro-face USB Data Transfer Cable" under the Pro-face devices.

Troubleshooting: If you see "Unknown Device," disable driver signature enforcement on Windows 10/11 (as Pro-face drivers are often unsigned or test-signed) or use an Ethernet transfer instead.

Understanding the GP-4402WW Hardware

Before discussing the software, it is crucial to understand what the GP-4402WW is. Part of Pro-face’s G4000 series, this model features:

  • Display: 7.5-inch wide SVGA (800 x 480 pixels) TFT color LCD.
  • Touch Panel: Analog resistive film (durable for industrial gloves).
  • Connectivity: Ethernet (10/100BASE-T), serial (RS-232C/422/485), and USB ports (Type A for peripherals, Type Mini-B for transfer).
  • Memory: 16 MB of user application storage (Flash EPROM) and 32 MB of SDRAM.

The "WW" in the model number typically indicates the worldwide version, supporting multiple language fonts and universal power inputs (24 VDC). Without the correct software tools, this hardware is simply a blank screen.

Third-Party Software Integration

While GP-Pro EX is the primary tool, the GP-4402WW can interact with other software via: