The Hager BP 10140 is a digital time switch (often cross-referenced with model EG103) designed for automated electrical load management. Core Features
Programmable Scheduling: Allows for precise timing of electrical loads, such as lighting or heating, using a digital interface.
Manual Override: Includes a physical switch or toggle to manually turn the connected device ON or OFF, bypassing the programmed schedule for maintenance or immediate needs.
DIN Rail Mounting: Designed for standardized installation within electrical distribution boxes.
Power Reserve: Many Hager digital switches in this series feature a battery backup (typically around 200 hours) to maintain timing settings during power outages.
LCD Display: Provides a digital readout for current time, status, and menu navigation during setup. Manual & Technical Details
The "BP 10140" designation refers to the manufacturing unit location in Saverne, France (B.P. 10140, 67703 Saverne Cedex), which is often printed on the product label alongside the actual model number, such as the . HAGER CONTROLS EG103 / BP 10140 / GC0521 ... - eBay
In the quiet, humming corridors of the Sterling Heights High-Rise, every light and shadow was governed by a silent sentinel: the Hager Controls BP 10140. It was a sleek, digital brain housed in a gray casing, its LCD screen glowing with a faint, reassuring amber.
Arthur, the building’s veteran technician, treated the manual like a holy text. To him, the BP 10140 wasn’t just a switch; it was the building's heartbeat. On Monday morning, he would consult the Manual Activation section. With a rhythmic press of the push-switches, he would bypass the automation to test the emergency stairwell lights, watching the status display flicker to life to confirm each output was active.
The real magic happened at dusk. Using the Scene Function described on page 12, Arthur had programmed the "Evening Glow". As the sun dipped, the Hager controller would command the window blinds to descend—not all at once, but with a precise slat position control that allowed exactly three inches of moonlight to spill onto the lobby floor.
One stormy Tuesday, the "3 Alarms" system went off. A sensor had detected a forced position override from a higher-level controller—a glitch in the main grid. Arthur didn’t panic. He opened the Hager Pilot App on his tablet, connecting via the local WIFI router.
With a few swipes, he re-synchronized the time switching functions. He watched the digital clock on the BP 10140 realign, its microprocessor humming as it resumed its "on schedule" routine. As the storm raged outside, the building remained a beacon of perfectly timed comfort, all thanks to a small gray box and a man who knew exactly which toggle to move to the "Auto" position.
- manual activation of the outputs on the device possible, building site operation - Status display of the outputs on the device - Device components - Hager
Hager BP 10140 is not a specific device model but rather the postal box address for Hager Controls S.A.S.
(B.P. 10140, 67703 Saverne Cedex, France) printed on various product manuals. However, this address is most frequently associated with the Hager EG103
digital time switch in second-hand markets and technical documentation. device.report Device Report: Hager EG103 Digital Time Switch
This report covers the digital time switch often identified by the Hager Controls address "BP 10140." 1. Key Features & Functions Single Channel Programming : Supports 24-hour and 7-day scheduling. Operating Modes
: Features automatic mode, continuous ON, and continuous OFF. Memory & Backup
: Retains programmed data even during power outages via an internal battery; however, date and time may be lost if the battery is changed without mains voltage. User Interface
: Includes a digital LCD display showing the current time, date, and automatic status. 2. Installation Guidelines : Designed for standard 35 mm DIN rail Connect the wire directly to the load (e.g., light). Connect the wire to the timer's line terminal. Connect the hager controls bp 10140 manual
to terminal 2, ensuring the line to the load passes through the timer.
: Must be installed by a qualified electrician in accordance with national safety standards. device.report 3. Programming Instructions Accessing Menu : Press the button to exit automatic mode and enter the programming ( ) interface. Setting Days
: Select individual days (1=Monday to 7=Sunday) or groups (weekdays/weekends) using the buttons and confirming with Setting Times
: Program the "ON" time first, followed by the "OFF" time. Confirm each hour and minute selection with Verification
: Use the "Viewing Mode" (indicated by an eye symbol) to scroll through and verify programmed events. 4. Technical Support & Manuals
Detailed technical documentation and specific device manuals can be found on the Hager Support Downloads page or via the Hager India Technical Catalogue Ed 10140 - device.report
Section 3: How to Find the Official Hager Controls BP 10140 Manual
Finding manuals for legacy or niche industrial equipment can be frustrating. Here is a step-by-step strategy:
The Ultimate Guide to the Hager Controls BP 10140 Manual: Troubleshooting, Installation, and Maintenance
Phase 3: Creating a Switching Program
The BP 10140 typically uses a "block programming" method:
- Press Prog (Program).
- Select the Channel you want to program (e.g., Channel 1 for exterior lights).
- Select On Time: e.g., 18:30.
- Select Off Time: e.g., 23:00.
- Select Days of Week: Choose individual days (Mo, Tu, We) or a block (Mo-Fr, Sa-Su).
- Save the program.
Common Error Codes & Troubleshooting (From the Manual)
Here are issues users face when they lose their Hager Controls BP 10140 manual:
| Error Display | Probable Cause | Solution | | :--- | :--- | :--- | | "Err 1" | Time not set after power outage | Reset the clock and date. Replace backup battery. | | "SERVICE" | Internal relay cycle count exceeded | Device needs replacement. Internal wear is irreversible. | | Flashing "AUTO" | Override active or voltage dip | Press Manual button to return to Auto mode. | | No Display | No supply voltage or blown internal fuse | Check incoming voltage (L-N). Replace fuse (refer to manual for fuse rating). | | Load doesn't turn off | Welded relay contacts or wrong program | Turn off main power. Check for zero-crossing failures. Replace unit. |
Q3: The manual says “use only with Hager busbar system.” Which one?
Based on form factor, it may fit the Hager KDC or KDX series busbar comb. Measure center-to-center spacing (likely 17.5mm or 40mm).
Q2: How do I reset the BP 10140 to factory settings?
A: Usually, there is a small "Reset" pinhole near the battery compartment. Press and hold for 5 seconds. Alternative: Remove power and the backup battery simultaneously for 10 minutes.
Conclusion
The Hager Controls BP 10140 manual is your roadmap to mastering this robust industrial timer. Whether you need to wire it into a new heating system or troubleshoot a lighting circuit that refuses to turn off, the manual provides the authoritative answers.
Action Steps:
- Download the official PDF from Hager’s support portal today.
- Print the wiring diagram page and tape it inside the electrical panel door.
- Check the backup battery every 12 months.
By respecting the guidelines laid out in the manual, you ensure safety, extend the lifespan of your device, and maintain precise control over your electrical loads. If you cannot locate the original document, treat this guide as a starting point—but always verify terminal labels and voltages with a qualified electrician before handling live equipment.
Disclaimer: This article is for informational purposes only. Always refer to the official Hager documentation provided with your specific product revision. Electrical work carries risk of injury or death; consult a licensed professional.
address for Hager Controls S.A.S. in Saverne, France. Because this address appears in the footer of almost every manual produced by Hager, it is often mistaken for a specific device part number.
To find the correct manual, you must locate the specific Product Reference Code (typically formatted as letters followed by numbers, like EG103, EH011, or TJA470) printed on the front or side of your device. Identifying Common Hager Control Devices
If your device resembles any of the following, these are the general operating principles: The Hager BP 10140 is a digital time
Digital Time Switches (e.g., EG103): Often found in industrial settings for scheduling power to specific circuits.
Analogue Timers (e.g., EH011, EHN011): Feature a large 24-hour dial with small pins (tabs) representing 15-minute intervals. Pushing these pins in or out sets the "on" or "off" schedule.
KNX Control Servers (e.g., TJA470/TJA670): Smart home servers used to link local networks to KNX automation systems via applications like domovea.
Coviva Controllers: Smart building hubs that use an app (Hager Pilot) for configuration and feature RGB status displays. How to Retrieve Your Specific Manual
Locate the Reference Code: Look for a string such as EG103, EH711, or TYA62 on the device label.
Use the Hager Download Center: Search for the reference code on the official Hager technical database to download the PDF manual.
Check for Mobile Apps: For modern smart controllers, search for the Hager Pilot or domovea apps on the App Store or Google Play Store for digital setup guides. Standard Safety Warning
For any Hager device—whether a circuit breaker or a timer—installation must only be performed by a qualified electrician according to national standards to avoid electric shock or fire hazards. Downloads - Hager
The Hager BP 10140 is the technical model reference for the back panel component of the Hager EG103 digital time switch. Because these parts are typically sold and operated together, the EG103 / BP 10140 Manual provides the essential instructions for installation and programming. Mastering Your Hager EG103 / BP 10140 Digital Time Switch
Managing your home or business's energy efficiency often comes down to the small things—like precisely when your lights, heaters, or pumps turn on and off. If you’ve found yourself looking at a Hager BP 10140 back panel, you’re likely working with the reliable Hager EG103 series. What is the Hager BP 10140?
While "BP 10140" is the identification number printed on the white plastic back panel, it is most commonly paired with the Hager EG103 digital time switch. This device is a weekly programmable timer designed to automate electrical loads, ensuring they only run when needed. Key Programming Features
The device features an LCD display and four main control buttons to manage its functions:
Weekly Scheduling: Program specific "on" and "off" times for different days of the week.
Programming Key (Optional): For complex setups, you can use a physical programming key to "save" or "load" programs between different switches without manual entry.
Manual Overrides: You can temporarily bypass the current program by using the front buttons to toggle the connected load manually. Essential Manual Steps
If you are setting up or troubleshooting your unit, keep these manual highlights in mind:
Safety First: Installation should always be performed by a qualified professional. Ensure the power is off before mounting the device to the BP 10140 back panel.
Accessing the Menu: Use the "OK" and arrow buttons to navigate through time setting, date adjustment, and program creation.
Loading Programs: If using a programming key, wait two seconds after insertion to select between "save" (copying to the key) or "load" (copying to the switch). Press Prog (Program)
Status Check: The display will show a 0 for OFF and a 1 for ON, giving you instant visual feedback on the current switching state. Where to Find the Full Manual
For a complete list of wiring diagrams and technical specifications, you can download the official Hager EG103 Instruction Manual directly from Hager's technical resource library.
The Hager BP 10140 is a digital time switch, often associated with or listed under the model number Go to product viewer dialog for this item.
. While "BP 10140" refers to the postal address of Hager Controls S.A.S. in France (Boîte Postale 10140), it is frequently found on the device's labeling. Key Features & Operations
The following features are typical for digital time switches in this series, such as the Hager EGN103
Programming Modes: You can select a programming mode using the menu and ok buttons to set specific day/time schedules.
Manual Override: Most models include a manual override button or switch. For example, some Hager switches have a three-position toggle: 1: Continuously ON. Clock Icon: Automatic timer operation. 0: Continuously OFF.
Display: Digital models typically show the current time, status of the output (ON/OFF), and the remaining free program steps during setup
Time Intervals: While analog versions often use 15-minute pins, digital models like the allow for more precise minute-by-minute scheduling. Configuration Steps
Enter Program Mode: Press menu, select "prog mode," and confirm with ok.
Select Days: Use the + or - buttons to choose the day or group of days for the schedule.
Set Status: Choose whether the output should be "On" or "Off" at the specified time.
Set Time: Input the hours and minutes using the navigation buttons and confirm each with ok. Resources & Downloads
Official Manuals: You can find technical documentation and user instructions on the Hager Download Center.
Video Guide: For visual learners, there are short tutorials on setting up similar 24-hour Hager timers on YouTube. Downloads - Hager
The Hager BP 10140 is not a specific model number, but rather a reference to the manufacturer's postal address (B.P. 10140) located in Saverne, France. This address appears on various Hager device manuals, including timers like the EG103, EHN011, and the B.IQ push button display.
If you are looking for a manual for a specific Hager control device found with this address, common models include the EG103 Digital Time Switch and the EHN010/011 Analog Timers. 1. Hager EG103 Digital Time Switch Manual The EG103 is a 1-channel weekly digital timer.
Time and Day Setting: Use the + or - keys to scroll through minutes, hours, and days. Programming: Press menu, select prog, and press ok. Select the day or group of days (1 = Monday, 7 = Sunday). Choose the state (On or Off).
Enter the switching hour and minutes, confirming each with ok.
Resetting: To clear all programs and time, press and hold +, -, ok, and menu simultaneously. 2. Hager EHN010 / EHN011 Analog Timer Manual
These are daily cycle time switches typically mounted on a DIN rail. Ed 10140 - device.report