Ic 2000 P Manual: Merlin Gerin Multi 9
Merlin Gerin Multi 9 IC2000P — Quick Post
Looking for the Merlin Gerin Multi 9 IC2000P manual? The Multi 9 IC2000P is a modular industrial control/relay interface unit used in electrical distribution and automation panels. For installation, wiring, and safe operation, consult the official product manual which covers:
- Product overview and typical applications
- Technical specifications (voltage, current ratings, contact configuration)
- Dimensions and mounting instructions
- Wiring diagrams and terminal assignments
- Connection examples with upstream breakers and downstream loads
- Safety warnings, required protective device coordination, and grounding instructions
- Commissioning, testing, and maintenance procedures
- Troubleshooting table and spare parts list
Important: Always follow local electrical codes and have a qualified electrician perform installation.
If you want, I can:
- Find and summarize the official manual (PDF) and list key wiring diagrams and specs.
- Draft a short social-media post or forum message linking to the manual and highlighting key safety points.
- Create a step-by-step quick-install checklist (assumes common electrical panel conditions).
Which would you like?
4.4 Mechanical Features
- Mechanical endurance: 10,000+ operations
- Mounting: Symmetrical DIN rail (35mm)
- Terminal type: Cage-clamp or screw terminals with specific wire ranges (e.g., 0.5 mm² to 2.5 mm² rigid/stranded)
Complete Guide: Merlin Gerin Multi 9 IC2000 P Manual – Specs, Wiring, and Troubleshooting
Product Type: Industrial Control Relay / Interface Relay
Brand: Merlin Gerin (now part of Schneider Electric)
Series: Multi 9
Model: IC2000 P
Q1: Is the Merlin Gerin Multi 9 Ic 2000 P a circuit breaker?
A: No. Most likely it is an auxiliary contact or control relay. A standard Merlin Gerin circuit breaker would have a thermal-magnetic trip curve (e.g., C, D, or B curve). The "Ic" designation stands for Interface and Control.
Part 6: Frequently Asked Questions (FAQ)
Q1: Can I use the Multi 9 Ic 2000 P for human protection? A: No. The manual clearly states this unit is for “protection of equipment and fire prevention.” For people, you need a 30mA RCD.
Q2: My manual is in French. Where is the English version? A: Merlin Gerin was a French company. The original English manual is a short translation. You can find the bilingual PDF by searching “Merlin Gerin Multi 9 Ic 2000 P Notice d’instruction” – often the second half is English.
Q3: Can I use this as a main switch? A: The manual allows it as a “load break switch” (rated for making and breaking load current up to 80A). However, it does not provide short-circuit protection. You must have a fuse or MCB upstream.
Q4: I lost the terminal shield. Is it required? A: Per the manual’s safety section, the terminal finger protection (shroud) is mandatory for IP20 compliance. Do not operate without it.
Method 1: Schneider Electric’s Obsolete Product Archive
- Go to the official Schneider Electric website.
- Navigate to Support → Download Center / Product Support.
- Enter the search term:
Multi 9 Ic 2000 P. - Select “Obsolete Documents.” If the PDF is not visible, click Request an obsolete document. Schneider’s technical support will email you the original datasheet + manual within 48 hours.
Final Verdict: Keep It or Replace It?
If you find a working IC2000 P in an existing panel, it is a robust, reliable unit. However, if it trips or fails the test button, do not search eBay for a used one. The modern equivalent is the Schneider Electric Acti9 iID (e.g., A9R41263).
Why replace? Newer RCDs have:
- Better immunity to nuisance tripping from surges.
- Higher short-circuit withstand (Icn).
- Easier busbar connections.
A Note on Obsolescence
The Multi 9 Ic 2000 P uses an electromechanical trip mechanism that degrades over time. The manual specifies a 15-year operational lifespan. If your unit is older than that (most are, as production ceased in the early 2000s), it is time to replace it with a modern equivalent: Schneider Electric A9N17954 (iID 4P 63A 2000mA).
8. Safety Reminder
- Always de-energize the panel before handling or replacing the relay.
- Do not exceed 6 A resistive or 4 A inductive load.
- Ensure proper creepage and clearance distances – the Multi 9 range is rated for basic insulation only.
Need a specific page from the manual? Reply with the exact diagram or parameter you’re looking for (e.g., “response time,” “LED color meaning,” “test button operation”) and I’ll extract it from the original Merlin Gerin documentation.
Last updated: 2025
Document ID: MG-IC2000P-MNL-EN-01
Merlin Gerin Multi 9 IC 2000P is a programmable twilight switch that combines light-sensitive detection with a time-based schedule to control lighting circuits. docs.rs-online.com Key Specifications Brightness Threshold: Adjustable from 2 to 2000 lux (or up to 2100 lux on newer models). Time Switch: Features a 24-hour and 7-day programmable memory with up to 42 settings Temporisation (Delay): Adjustable switching delay (typically 20 to 140 seconds Merlin Gerin Multi 9 Ic 2000 P Manual
, default at 80s) to prevent false triggering from car headlights or transient clouds. Power Supply: operation. Equipped with a battery backup providing up to of memory retention without power. Protection:
Rated for IP54 (photocell) and designed for indoor DIN rail mounting. docs.rs-online.com Operating Modes Automatic:
Lighting is activated ONLY if the ambient light is below the set threshold AND the time program is in an "ON" period. Manual Overrides:
Allows for forced "ON" or "OFF" states, bypassing the automatic sensors. Holiday Mode:
Can be set for specific dates to keep lighting off during absences. docs.rs-online.com Installation & Setup Tips Photocell Placement:
Mount the photocell vertically, away from direct artificial light sources or magnetic field devices (like contactors) to avoid interference. Use tunnel terminals for cables up to
. Do not run photocell connection cables (max 100m) in the same conduit as high-power 230V conductors.
Use the "Test" button to verify the relay clicks and the circuit triggers correctly. docs.rs-online.com For the full detailed manual, you can view the Acti 9- IC2000P+ Operating Instructions provided by Schneider Electric , the successor to the Merlin Gerin brand. Schneider Electric or a specific programming sequence for the 7-day schedule? light sensitive switches IC200, IC2000, IC2000P - RS Online 5 Jul 2001 —
technical data. # light detection part: same as IC2000. # brightness threshold: adjustable from 2 to. 200 lux. # time switch part: docs.rs-online.com light sensitive switches IC200, IC2000, IC2000P - RS Online 5 Jul 2001 —
technical data. # light detection part: same as IC2000. # brightness threshold: adjustable from 2 to. 200 lux. # time switch part: docs.rs-online.com light sensitive switches IC200, IC2000, IC2000P - RS Online 5 Jul 2001 —
The Merlin Gerin Multi 9 IC2000 P Go to product viewer dialog for this item.
is a programmable light-sensitive (twilight) switch designed to control electrical loads based on ambient light levels and pre-set time schedules. While specific user reviews are limited for this industrial component, its technical specifications and manuals highlight its functionality as a high-precision lighting management tool. Core Functionality
Dual Control: It combines the features of a standard light-sensitive switch with a single-channel programmable time switch.
Adjustable Thresholds: The brightness threshold can be adjusted from 2 to 2,000 lux.
Time Programming: It offers a 24-hour and 7-day switching cycle with a minimum programming interval of 1 minute and a memory capacity for up to 42 settings. Merlin Gerin Multi 9 IC2000P — Quick Post
Power Reserve: It includes a lithium battery that provides a power reserve of approximately 6 years to maintain program settings during power outages. Installation & Manual Highlights
Mounting: Designed for standard DIN rail mounting with a width of approximately 45mm (equivalent to 5 modules of 9mm).
Wiring: Uses tunnel terminals for cables up to 6 mm². It is critical not to run photocell cables (max 100m) in the same conduit as 230V power conductors to avoid interference.
Operational Priority: In "Night-Break" or hybrid modes, time-period settings typically override lux level settings to ensure precise control during specific hours. User Experience & Support
Display: Features a continuous liquid crystal display (LCD) showing the current time, day of the week, and switching status.
Manual Accessibility: Most units feature a dedicated manual holder on the left side of the product for easy access to instructions during maintenance.
Current Availability: Merlin Gerin has been integrated into Schneider Electric. Modern equivalents are often found under the Schneider Electric Acti9 IC2000P+ product line.
For detailed wiring diagrams and step-by-step programming, you can download the official instruction sheet from RS Components or the updated Acti9 IC2000P+ manual from Schneider Electric. light sensitive switches IC200, IC2000, IC2000P - RS Online
The Merlin Gerin Multi 9 IC 2000 P is a DIN-rail mounted, programmable twilight switch that manages lighting based on ambient light levels (2-2000 lux) and 7-day schedules. It operates on 230V AC, offers adjustable time delays to prevent flickering, and features a 16A dry contact output. For the full operating instructions, visit Schneider Electric
Manual Merlin Gerin IC2000P (page 1 of 2) (English) - Libble.eu
The Merlin Gerin Multi 9 IC 2000 P Go to product viewer dialog for this item.
(now often branded under Schneider Electric's Acti 9 range as the IC2000P+) is a programmable twilight switch designed to control lighting or other electrical loads based on both light intensity and a weekly time schedule. Key Manuals and Documentation
Operating Instructions (Official): The most comprehensive guide is the Acti 9 IC2000P+ Operating Instructions, which covers wiring, initial setup, and advanced programming.
Technical Overview: For a summary of technical data, such as power consumption (0.8W standby) and switching capacity (10A–16A), refer to the IC2000P Technical Datasheet.
Installation Guide: A legacy Merlin Gerin IC2000 Installation Guide provides specific diagrams for mounting the external photocell and basic wiring. Core Functions and Features Important: Always follow local electrical codes and have
Dual Control: It combines light-sensitive switching (adjustable from 2 to 2000 lux) with a 7-day (weekly) programmable timer.
Programming Capacity: Supports up to 56 switching operations and includes a lithium battery for a 5–10 year power reserve.
Override Options: Features manual and remote override capabilities, allowing you to force the load on or off regardless of the current program or light level.
Automatic Adjustments: Includes automatic winter/summer time changeover and a holiday schedule mode. Basic Programming Steps
Upon first power-up or after a reset, you must complete the following initial setup: Language: Select your preferred language (e.g., English). Date/Time: Set the current year, month, day, and time.
Light Threshold: Access the LIGHT menu to adjust the brightness threshold (lux) and set switching delays to prevent flickering from transient light (e.g., car headlights).
Schedule: Use the PROGRAM menu to define "On/Off" periods for specific days of the week. Wiring and Installation Tips
Photocell Placement: Mount the external sensor vertically using the provided IP54 housing. Do not place it near magnetic devices (transformers, contactors) or directly under the light it is controlling.
Cabling: Use separate conduits for photocell cables and 230V AC power conductors to avoid interference. Maximum photocell cable length is 100 meters.
High Power Loads: While it can directly control loads up to 1000W, use a contactor for higher power requirements or inductive loads to protect the internal relay.
In the heart of a bustling industrial complex, where the hum of machinery was the symphony of progress, there stood a modest electrical cabinet. Within its steel confines, amidst a maze of wires and components, resided the Merlin Gerin Multi 9 Ic 2000 P. It was not merely a circuit breaker; it was a silent guardian, a sentinel of safety.
The Ic 2000 P had been installed years ago, its sleek, grey casing a testament to the engineering prowess of Merlin Gerin. Its purpose was clear: to protect the delicate electronic systems of the facility from the ravages of overloads and short circuits. It was a role it embraced with unwavering dedication.
Day and night, the Ic 2000 P monitored the flow of electricity. It was a constant vigilance, a tireless watch against the unseen forces that could disrupt the factory's rhythm. The manual, a weathered document tucked away in a nearby folder, was its guiding light, containing the secrets of its operation and the wisdom of its creators.
One sweltering afternoon, a sudden surge of power rippled through the electrical grid. It was a formidable force, a digital tempest that threatened to overwhelm the factory's systems. The Ic 2000 P felt the surge, its internal sensors reacting with lightning speed. Within milliseconds, it tripped, its mechanical heart snapping shut, severing the path of the destructive current.
The factory fell silent. The hum of machinery was replaced by an eerie stillness. But in that silence, there was safety. The Ic 2000 P had fulfilled its duty, preventing a potentially catastrophic event.
The facility's electricians, guided by the manual, soon arrived at the cabinet. They examined the tripped breaker, its indicator window a clear sign of its heroic intervention. With careful hands, they reset the Ic 2000 P, restoring power to the factory.
The machines roared back to life, their symphony resumed. The Ic 2000 P returned to its silent watch, its grey casing a symbol of reliability and protection. It was a modest component, but its story was one of unwavering commitment to safety, a story told in the quiet corners of the industrial world.