The RSLogix Project Migrator (also known as the Translate PLC-5 SLC 2.0 Tool) is a free utility used to convert legacy PLC-5 and SLC-500 projects into the Studio 5000 Logix Designer platform. How to Download and Access
The tool is not typically downloaded as a standalone installer but is instead automatically included with the installation of Studio 5000 or RSLogix 5000 software.
Standard Path: After installing Studio 5000, you can find it under the Windows Start Menu at:
Rockwell Software > RSLogix 5000 Tools > RSLogix Project Migrator.
Alternative File Locations: Depending on your software version, the executable might be located in the installation directory: v21: \Studio5000\Tools\Translate PLC-5 SLC 2.0 Tool. v24+: \Studio5000\Tools\RSLogix Project Migrator. rslogix project migrator tool download free
Manual Download: If you do not have the software installed, the tool is often available as a free standalone download via the Rockwell Automation Compatibility & Downloads site by searching for "RSLogix Project Migrator" or looking up Tech Note AID 69790. Key Features and Capabilities
Platform Conversion: Facilitates the transition of applications written for legacy systems (PLC-5 or SLC) to the modern Logix 5000 environment.
Database Migration: Allows you to migrate address descriptions, rung comments, and symbols by importing database files (typically in .TXT or .CSV format).
Partial Automation: While it handles the bulk of the conversion, it is not a "100% solution." Instructions that do not have a direct equivalent in Studio 5000 are flagged as conversion errors for manual review. The RSLogix Project Migrator (also known as the
IO Strategy Options: Provides configurable options for how I/O modules and strategies are handled during the migration process.
Alias Tag Creation: Features a setting to automatically import legacy symbols as "Alias tags" in the new project to maintain consistency with the old logic. Basic Migration Workflow
Preparation: Open the legacy project in RSLogix 5 or 500 and save it as an .ACH (PLC-5) or .SLC (SLC-500) file.
Database Export: Export comments and symbols from the legacy software into a .TXT or .CSV file to ensure they transfer correctly. ❌ Cracked/pirated migrators – Often malware, no support
Run Migrator: Launch the tool, select the legacy file and its corresponding database file, and choose your target Logix controller and software version.
Finalize: The tool generates an .ACD file that can be opened directly in Studio 5000 Logix Designer.
Please note: The official tool provided by Rockwell Automation is typically the "Project Migrator" utility found within the FactoryTalk Linx (formerly RSLinx) or as a standalone migration suite. It is generally included with paid Rockwell software activations, though older legacy tools may be found in archives.
Rockwell once offered a standalone RSLogix Project Migrator installation file (roughly 150 MB) via their Product Compatibility & Download Center (PCDC). As of 2025, this utility remains free to download, but you must have an active Rockwell Automation Support Agreement. Without a support contract, you cannot log into the download portal.