Studio 5000 V35 Release Notes Page
Studio 5000 Logix Designer Version 35.00 focuses on expanding hardware support for process industries, enhancing motion virtualization, and introducing modern web-based device configuration tools. Key New Features
Expanded Process Hardware Support: Includes SequenceManager expansion for 5x80P controllers, bringing process-specific functionality to the latest controller technology.
Axis-Test Mode: Allows for virtualized motion testing for Kinetix, PowerFlex, and iTRAK 5730 CIP Motion devices without physical hardware. It works with physical controllers or emulated ones via FactoryTalk Logix Echo.
New Process Instructions: Three new embedded instructions—P_SD (Discrete Device), P_nPOS (n-Position Device), and P_valveMP (Mix Proof Valve)—to streamline PlantPAx programming.
Web-Based Add-On Profiles (AOP): Updated device profiles now use a modern, web-based interface for a consistent configuration experience across platforms.
Logix Designer SDK: Alignment with a new SDK allows users to write C++ scripts to automate repetitive tasks within the Designer environment. System Improvements
Controller Change Detection: Expanded support for ControlLogix 5580 controllers to better track project changes.
I/O Tree Enhancements: Ability to cut, copy, and paste multiple devices simultaneously to reduce manual editing time. Editor Shortcuts: New navigation shortcuts (
) added to Sequential Function Chart (SFC) and Function Block Diagram (FBD) editors. Hardware Requirements RSLogix/Studio 5000: Windows 11 Compatibility
Studio 5000 View Designer versions 9.01 and higher are compatible with Windows 11 Professional or Enterprise Edition. Rockwell Automation
( 9324-RLDx ) Studio 5000 programming software. ... - Release Note
Studio 5000 V35 Release Notes
Introduction
Studio 5000 is a comprehensive software solution for the design, operation, and maintenance of integrated control and information systems. The latest release, Studio 5000 V35, offers a range of new features, enhancements, and improvements to help users optimize their control and automation projects. This document provides a detailed overview of the new features, changes, and known issues in Studio 5000 V35.
New Features
- Enhanced Security: Studio 5000 V35 introduces enhanced security features to protect users' intellectual property and ensure the integrity of their control systems. These features include:
- Encrypted project files to prevent unauthorized access
- Secure online collaboration and sharing of projects
- Improved password management and authentication
- Improved Performance: The latest release offers significant performance improvements, including:
- Faster project compilation and download times
- Enhanced responsiveness of the user interface
- Improved handling of large and complex projects
- New Controller Support: Studio 5000 V35 adds support for new controllers, including:
- CompactLogix 5480
- ControlLogix 5580
- MicroLogix 1400
- Enhanced HMI Features: The HMI (Human-Machine Interface) capabilities in Studio 5000 V35 have been enhanced with:
- New visualization tools for improved data analysis and presentation
- Enhanced alarm and event management
- Support for third-party HMI devices
- Integration with Other Rockwell Automation Products: Studio 5000 V35 offers improved integration with other Rockwell Automation products, including:
- FactoryTalk View ME and SE
- FactoryTalk Historian
- FactoryTalk VantagePoint
Enhancements and Changes
- Updated User Interface: The Studio 5000 user interface has been updated to provide a more modern and intuitive look and feel.
- Improved Project Management: The project management capabilities in Studio 5000 V35 have been enhanced with:
- Improved project navigation and organization
- Enhanced search and filtering capabilities
- Support for project templates
- Changes to Add-On Instructions: The Add-On Instructions (AOIs) in Studio 5000 V35 have been updated to:
- Improve performance and reduce overhead
- Enhance usability and flexibility
- Updated Help and Documentation: The help and documentation for Studio 5000 V35 have been updated to:
- Provide more detailed and accurate information
- Offer improved navigation and search capabilities
Known Issues
- Controller Firmware Compatibility: Some controller firmware versions may not be compatible with Studio 5000 V35. Users should verify the compatibility of their controller firmware before upgrading.
- Project Compatibility: Projects created in earlier versions of Studio 5000 may require conversion to be compatible with V35.
- HMI Display Issues: Some HMI displays may not function correctly in certain configurations.
System Requirements
- Operating System: Studio 5000 V35 supports Windows 10 (64-bit) and Windows 7 (64-bit) SP1.
- Processor: Intel Core i5 or equivalent processor.
- Memory: 8 GB RAM or more.
- Graphics Card: NVIDIA GeForce or equivalent graphics card.
Upgrade and Installation Instructions
- Backup Existing Projects: Before upgrading to Studio 5000 V35, backup all existing projects and data.
- Uninstall Previous Versions: Uninstall any previous versions of Studio 5000 before installing V35.
- Run the Installer: Run the Studio 5000 V35 installer and follow the prompts to complete the installation.
Conclusion
Studio 5000 V35 offers a range of new features, enhancements, and improvements to help users optimize their control and automation projects. The latest release provides enhanced security, improved performance, and new controller support, among other features. Users should review the known issues and system requirements before upgrading to ensure a smooth transition. Rockwell Automation recommends that users upgrade to Studio 5000 V35 to take advantage of the latest features and improvements.
1. System Requirements & Compatibility (Read Before Installing)
Before downloading, verify your infrastructure meets these hard requirements.
2.4 Simulation & Emulation
Emulate V35 (Standalone)
- Supports eight controllers simultaneously on a single PC.
- Integration with FactoryTalk Logix Echo (version 2.0 or higher) for hardware-in-the-loop (HIL) testing.
- New: Emulate now replicates security certificate behavior of physical hardware.
Conclusion: Should You Upgrade to Studio 5000 V35?
Upgrade immediately if:
- You require CIP Security V2 or digital signatures for compliance (e.g., IEC 62443, NERC CIP).
- Your projects exceed 100,000 tags and V34 performance is suffering.
- You are deploying new 5069-L320ER or 1756-L81E controllers.
Wait for V35.01 if:
- You heavily rely on Kinetix 5700 ring topologies (EN4TR bug).
- Your site mandates a single Windows locale (non-English) and you use the Compare Tool daily.
- You have a stable V34 environment with no security mandates.
Final Verdict: V35 is a mature, performance-driven release with meaningful security upgrades. The resolved anomalies list is impressive, and the known issues have straightforward workarounds. For greenfield projects or regulated industries, V35 is the recommended baseline as of this writing.
Disclaimer: Release notes are accurate as of the general availability date. Rockwell Automation may release minor revisions (35.01, 35.02) that address issues noted above. Always consult Rockwell’s Product Compatibility and Download Center (PCDC) before production deployment.
Studio 5000 Logix Designer Version 35 enhances industrial automation by expanding support for Flex5000 and Compact 5000 I/O while improving logic engine performance for high-speed motion. The update advances digital transformation through refined Sequence Manager capabilities, enhanced Logix Echo emulation, and strengthened CIP Security for granular device authentication. For details, refer to Rockwell Automation.
Studio 5000 Logix Designer V35: Release Notes & Key Features
Rockwell Automation released Studio 5000 Logix Designer Version 35 in late 2022, introducing significant productivity enhancements, expanded hardware support, and advanced virtualization capabilities. This release focuses heavily on process industry requirements and motion simulation. Key Features and Enhancements
Virtual Motion Support (Axis-Test Mode): A highly requested feature that allows developers to test motion applications for Kinetix, PowerFlex, and iTRAK devices without physical hardware. It works in conjunction with FactoryTalk Logix Echo V2 to virtualize motor and drive behavior during design.
Embedded Process Instructions: V35 adds three new instructions directly into the software to streamline PlantPAx applications: PD4SD: Process Discrete 2-, 3-, or 4-State Device. PNPOS: Process n-Position Device. PVLVMP: Process Mix Proof Valve.
SequenceManager Expansion: Added support for 5x80P (Process) controllers, allowing them to utilize advanced sequencing functionality.
User Scripting (SDK): For the first time, Studio 5000 offers a publicly available SDK that allows users to write C++ script commands to automate repetitive tasks within the Logix Designer environment. Studio 5000 V35 Release Notes
Modernized UI: Updated device configuration with a web-based Add-On Profile (AOP) interface to provide a more consistent experience across different Rockwell software platforms. Hardware and System Requirements
To run Studio 5000 V35 effectively, your system should meet the following Product Compatibility & Download Center (PCDC) specifications: Characteristic Recommended Processor Intel Core 2 Duo (2.8 GHz) Intel Core i5 (2.4 GHz) RAM 8 GB Hard Disk Space 16 GB free 20 GB free Operating System Windows 10 v1703 or later Windows 10/11 Professional
Note: For communication, you must use FactoryTalk Linx 6.31 or later to support V35 firmware. Important Anomalies and Workarounds Release Note - Rockwell Automation Compatibility
8. Frequently Asked Questions (FAQ)
Q: Can I co-install V35 with V33 or V34 on the same PC?
A: Yes. Studio 5000 versions are side-by-side compatible. However, FactoryTalk Linx version 6.30 will be shared across all.
Q: Does V35 support Windows 11 ARM (e.g., Surface Pro X)?
A: No. x64 emulation of Logix Designer is not supported. Use native Intel/AMD hardware.
Q: Will my third-party HMI (Ignition, VTScada) work with V35 controllers?
A: Yes, as long as they use standard OPC DA/AE or Ethernet/IP via EDS files. CIP Security may require HMI updates.
Q: How do I disable digital signature enforcement for testing?
A: Controller Properties → Security → Set "Signature Enforcement" to "Warning Only" (not recommended for production).
Q: What is the end-of-life (EOL) for V35?
A: Rockwell’s standard policy: 5 years from release (October 2028) for critical updates. Extended support available until 2030.
3.1 Operating Systems (Official Support)
| OS | Version | 32-bit | 64-bit | |----|---------|--------|--------| | Windows 11 Pro/Enterprise | 21H2+ | No | Yes | | Windows Server 2022 | Standard/Datacenter | No | Yes | | Windows 10 IoT LTSC 2021 | 21H2 | No | Yes |
Deprecated: Windows 7, Windows 8.1, Windows Server 2016, and Windows 10 versions prior to 21H2.