Manual | Wella Climazon Millenium
The Wella Climazon Millennium is a high-performance infrared hair processor designed to speed up chemical treatments such as coloring, perming, and drying
. It features a distinctive design with five infrared heating elements, including foldable and adjustable side arms that can be positioned for optimal heat distribution around the client's head. Wella Professionals Key Controls and Features Heating Elements
: Five emitters, including adjustable side arms that can be moved into three different positions. Digital Control Panel
: Features a large text-based display and 10 function buttons for selecting treatments and adjusting settings. Customer Temperature Button
: Allows clients to manually lower the treatment temperature for added comfort. Operating Indicators wella climazon millenium manual
: Status lights blink three minutes before a treatment ends and signal error states. Mounting Versions
: Available as a mobile pedestal version (ST5) on wheels or a wall-mounted version (Acrobat 2004). Wella Professionals Main Treatment Programs
The device includes specialized software-controlled programs to ensure consistent results: Wella Professionals
: Optimizes temperature for hair dye, reducing processing time by up to 33%. Highlights/Bleaching : Precise heat application for lifting hair color safely. : Even heat distribution to ensure uniform curl patterns. The Wella Climazon Millennium is a high-performance infrared
: Modes for both standard and natural drying, functioning similarly to a hood dryer.
: Gentle heat for intensive conditioning treatments and hair masks. Wella Professionals Maintenance and Safety
: Before cleaning, turn off the main switch and unplug the unit. Use a soft, damp cloth with mild detergent; avoid flammable substances like benzene or thinners. Temperature Sensor
: Ensure the sensor's protective filter is clean to maintain accurate heat readings. Do not immerse any part
: To remove the unit from its pedestal, use a screwdriver to release the internal locking mechanism between the two small "legs" of the latch. Wella Professionals
5. Maintenance Schedule (Prescriptive from Manual)
| Component | Frequency | Action | | :--- | :--- | :--- | | Outer hood surface | Daily | Wipe with damp cloth and mild detergent. No abrasives. | | Quartz infrared tubes | Weekly | When cool, wipe with dry lint-free cloth. Oils from hands reduce tube life by 40%. | | Swivel joint bearings | Monthly | Apply one drop of silicone lubricant. Do not use WD-40. | | Timer mechanism | Annually | Professional inspection of internal contacts. | | Power cord | Every 6 months | Check for fraying near the strain relief. |
Prohibited actions (red box in manual):
- Do not immerse any part.
- Do not operate with a damaged reflector (causes hot spots).
- Do not cover the top ventilation grilles—risk of internal fire.
4. Safety Features
- Tilt Switch: The Climazon is equipped with a safety tilt switch. If the machine is knocked over or tilted at a dangerous angle, it will automatically cut power to the heaters to prevent fire hazards.
- Grille Guard: Ensure the metal grille at the back of the hood is never blocked. Blocking airflow can cause the unit to overheat and trip the thermal cut-out.
1. Introduction
The Wella Climazon is a professional salon heater/dryer designed for durability and precise temperature control. It is used forperms, color processing, and drying. The "Millennium" edition is characterized by its sturdy vertical design, manual dial controls, and independent heating elements.
Problem 3: Timer Doesn't Ring
- Cause: Mechanical bell spring is worn.
- Solution: Not critical for function—use a separate phone timer. The manual acknowledged this as a “non-repairable wear part.”
| 