This guide provides the necessary steps to install the USB driver for Xinje PLCs, specifically for the XC, XD, and XL series. Installing this driver is essential for the XCP Pro or XDPPro software to communicate with your hardware. 🛠️ Prerequisites
Software Installed: Ensure you have XCP Pro (XC series) or XDPPro (XD/XL series) installed.
Hardware: A Xinje PLC and a standard USB programming cable (usually USB-A to USB-B).
Operating System: Windows 7, 10, or 11 (64-bit recommended). ⚙️ Installation Procedure 1. Connect the Hardware Power on your Xinje PLC. Connect the USB cable to the PLC and your PC. Windows will likely fail to find the driver automatically. 2. Locate the Driver Files
The drivers are bundled with the programming software. They are usually found in the installation directory: Path: C:\Program Files (x86)\XCPPro\USB_Driver Alternative Path: C:\Program Files (x86)\XDPPro\USB_Driver 3. Update via Device Manager Right-click the Start button and select Device Manager.
Look for "Unknown Device" or "Xinje PLC" under "Other devices" (usually marked with a yellow exclamation icon). Right-click the device and select Update driver. Choose "Browse my computer for drivers".
Click Browse and navigate to the USB_Driver folder identified in Step 2. Click Next. Windows will install the driver. 4. Verify the Connection
In Device Manager, check under Ports (COM & LPT) or Universal Serial Bus controllers.
You should see "Xinje PLC USB Driver" or a specific COM Port assigned. 🔗 Software Configuration
Once the driver is installed, you must tell the software which port to use: Open XCP Pro / XDPPro. Go to Option > Communication Setting.
Select USB as the transfer mode (if available) or select the COM Port number assigned in Device Manager. Click Check to test the connection. 💡 Troubleshooting Tips
Driver Signature: If Windows blocks the install, you may need to disable Driver Signature Enforcement.
Cable Quality: Always use a shielded USB cable to prevent communication timeouts in noisy industrial environments.
Manual Download: If the folder is missing, download the latest "USB Driver" package directly from the Xinje Official Download Center. If you'd like, I can help you with:
Finding the exact download link for your specific PLC model.
Step-by-step instructions for uploading/downloading code once connected. Setting up Modbus communication via the USB port.
To install the USB driver for a Xinje PLC, you typically need to install the Xinje PLC Programming Software (such as XDPPro or XS Studio), which includes the necessary driver files. 1. Identify Your PLC Series Xinje offers different software depending on the PLC model: XC Series: Uses XDPPro software.
XD/XL Series: Uses XDPPro (newer versions) or specific XD software. XS Series: Uses XS Studio (often based on CODESYS). 2. General Installation Steps
Download the Software: Visit the Xinje Download Center or regional sites like Xinje Malaysia to get the latest programming software for your specific series.
Run the Installer: Execute the setup file as an administrator. The USB driver installation is usually bundled with the main software installation. Manual Driver Installation (if needed):
If the PLC is not recognized after software installation, connect the PLC to your PC via the USB cable. Open Device Manager on your Windows PC.
Look for an "Unknown Device" or a device labeled "Xinje PLC" under "Other devices" or "Ports (COM & LPT)". Right-click the device and select Update Driver.
Choose Browse my computer for drivers and point to the Driver or USB folder within the Xinje software installation directory (typically C:\Program Files (x86)\Xinje...). Verify Communication: xinje plc usb driver install
In the Xinje programming software, go to Communication Settings.
Select the correct connection type (USB or Serial via a USB-to-RS232 adapter like the USB-XC). Test the connection to ensure the PC can "see" the PLC. 3. Key Hardware Drivers
Xinje TH USB Device: Common for various Xinje interfaces; version 1.0.5.0 is a known stable version for certain legacy hardware.
USB-XC Cable: If you are using a conversion cable (USB-XC), it may require a separate Prolific or CH340 serial-to-USB driver if not automatically installed by Windows. 4. Safety and Connection Tips
Power Off: Always cut off external power before performing initial wiring or connecting expansion modules.
Cable Types: High-speed motion controllers (like the XDC series) or Ethernet-capable models (like the XD5) might use standard USB or Ethernet cables, but standard XC/XD models often require specific programming cables. XINJE PLC XD5 Series Programmable Controller User Manual
Installing the Xinje PLC USB Driver
Xinje PLCs are popular programmable logic controllers used in various industrial automation applications. To connect a Xinje PLC to a computer via USB, you need to install the appropriate driver. Here's a step-by-step guide on how to install the Xinje PLC USB driver:
Pre-requisites:
Installation Steps:
Verifying the Installation:
Troubleshooting Tips:
By following these steps, you should be able to successfully install the Xinje PLC USB driver and connect your Xinje PLC device to your computer via USB. If you encounter any issues or have further questions, consult the Xinje documentation or contact their support team.
To successfully install and configure the USB driver for a , you must download the driver from an official source, install it manually through the Windows Device Manager if necessary, and then configure the corresponding COM port within the Xinje programming software (XDPPro or XCPPro). 1. Driver Acquisition and Installation
The USB driver is typically included with the Xinje programming software or available as a separate "COM-USB driver" download. : Access the official Xinje Download Center or the specific XD3 series product page to find the latest "COM-USB driver". Manual Installation
: If the driver does not auto-install when the PLC is connected: Windows Device Manager
Locate the device (it may appear under "Other devices" or "Ports" with a yellow exclamation mark). Right-click and select Update driver
, then browse to the folder where you extracted the downloaded driver. Wuxi Xinje Electric Co., Ltd. 2. Software Configuration
Once the driver is recognized as a "USB Serial Port (COMx)," you must link it to your programming environment. Software Identification for XD/XL series PLCs and for XC series models. Port Setup Comm Mode Settings Software Serial Port Config Select the specific number assigned in Device Manager.
. A successful connection will display a "Connect To PLC Succeeded" message. Wuxi Xinje Electric Co., Ltd. 3. Troubleshooting Connection Issues
If the "Connect To PLC Succeeded" prompt does not appear, verify the following: Hardware Check : Ensure you are using the correct RS232-USB converter cable or a direct USB cable if supported by your specific model. Driver Status
: Check Device Manager again. A yellow exclamation point indicates the driver is not working correctly and may need a fresh installation. This guide provides the necessary steps to install
: Ensure the PLC is powered on and not in a state that blocks communication.
: For standard serial-to-USB connections, the default baud rate is often , with Even parity and 1 stop bit. or help identifying the specific driver version for your Windows OS? Download Center - Wuxi Xinje Electric Co., Ltd.
Installing the Xinje PLC USB driver is a vital step for establishing communication between your PC and Xinje hardware, such as the XD, XL, or XC series. Without this driver, your programming software (like XDPPro or XS Studio) will not recognize the PLC through a USB or USB-to-Serial programming cable. Step 1: Download the Correct Driver
You can typically find the necessary drivers in the Download Center of the official Wuxi Xinje Electric Co. website.
Xinje TH USB Device: This is the most common driver for direct USB connections.
USB-to-Serial Drivers: If you are using a conversion cable (like the USB-XC), you may need standard serial drivers (such as CH340 or Prolific), which are often included with the cable or the PLC software installation. Step 2: Manual Installation via Device Manager
If Windows does not automatically install the driver upon connection, follow these steps to install it manually: Kylie Jmina USB-XC PLC Programming Cable Instruction Manual
Installing the USB driver for a Xinje PLC typically involves two parts: installing the programming software (which often includes the drivers) and verifying the connection in the Windows Device Manager. 1. Download and Install Programming Software
The drivers for Xinje PLCs are usually bundled with their official programming tools.
XDPPro (for XD/XL series): Download the latest version of XDPPro. During the setup of XDPPro V3.5.1, the installer will prompt you to install additional components like XNetSetup and SLabVirtualCOM, which are essential for USB communication.
XCPro (for XC series): Use this software for older XC1, XC2, XC3, and XC5 series PLCs.
Official Source: For the most up-to-date files, visit the Wuxi Xinje Download Center. 2. Physical Connection
Connect the USB-XC or USB-to-Serial programming cable to your PC's USB port.
Plug the 8-pin circular DIN connector into the PLC's programming port. Ensure the PLC is powered on. 3. Manual Driver Installation (If needed)
If Windows does not automatically recognize the cable, you may need to install the Xinje TH USB Device driver manually: Open Device Manager on your PC.
Locate the unrecognized device (often listed under "Other devices" with a yellow exclamation mark). Right-click the device and select Update driver.
Choose Browse my computer for driver software and navigate to the installation folder of your Xinje software (e.g., C:\Program Files (x86)\Xinje\XDPPro\USB_Driver).
Follow the prompts to finish the installation. Once successful, it should appear under Ports (COM & LPT) as a "USB-Serial Port". 4. Configure Communication in Software Open your programming software (e.g., XDPPro or XCPro). Go to Option > Software Serial Port Config.
Select the COM Port number that matches the one assigned in Device Manager.
If the connection is correct, you will see a message like "Connect To PLC Succeeded" in red text.
Safety Note: Always ensure the PLC is stopped before downloading a new program to prevent unexpected machine movement. How to Install Windows Drivers Manually
To install the USB driver for a , you typically need to install the COM-USB driver from the official Xinje website or ensure it is bundled with your programming software (like XDPPro or XCPPro). This driver allows your PC to recognize the USB-to-RS232 programming cable used for communication. Step-by-Step Installation Guide Download the Driver: Visit the official Xinje Download Center Xinje PLC device USB cable Computer with Windows
and look for the COM-USB driver or the specific driver for your series (e.g., XC, XD, or XL series). Alternatively, drivers for older devices like the Xinje TH USB Device
can sometimes be found through specialized driver repositories. Connect the Hardware: Plug your USB programming cable into your computer.
Note that many Xinje PLCs use a USB-XC cable, which is a USB-to-RS232 adapter with an 8-pin round head for the PLC port. Run the Installation:
Locate the downloaded .rar or .zip file, extract it, and run the setup file (often an .exe) with administrative rights. Follow the on-screen wizard to complete the installation. Verify in Device Manager: Open Device Manager on your Windows PC.
Look under "Ports (COM & LPT)" to find the newly assigned COM port number (e.g., COM3 or COM6).
If you see a yellow exclamation mark, right-click the device and select "Update driver," then browse to the folder where you extracted the driver files. Configure Programming Software:
Open your software (e.g., XDPPro for XD/XL series or XCPPro for XC series). Go to Option > Software Serial Port Config. Select the correct COM port identified in Step 4.
Click Comm-Test. If successful, you will see a message like "Connect To PLC Succeeded". Troubleshooting Tips
Administrative Rights: Always run the installer as an administrator to ensure Windows doesn't block the driver files.
Cable Check: Ensure you are using the correct cable for your series. The USB-XC cable is the standard for most XC, XD, and XL models.
Auto-Detection: If the connection fails, many Xinje software tools have an "Auto-detect" button in the communication settings that can scan available ports for you. Download Center - Wuxi Xinje Electric Co., Ltd.
Installing a Xinje PLC USB driver is a straightforward process, but it requires specific steps to ensure your PC communicates correctly with the hardware. Follow this guide to get your connection up and running. 🛠️ Prerequisites Before starting, ensure you have the following: A Xinje PLC (XC, XD, or XL series) USB Programming Cable (usually a standard USB-A to USB-B or Mini-USB) XDPPro or XDPro Software installed on your Windows PC Administrator rights on your computer 📂 Step 1: Locate the Driver Files
Xinje drivers are typically bundled with their programming software. You don’t usually need to download a separate installer. Default Path: C:\Program Files (x86)\Xinje\XDPPro\USB_Driver If you are using the newer
software, look in the corresponding installation folder for the USB_Driver directory. 🔌 Step 2: Connect the Hardware Power on your into the PLC and then into your computer.
Windows will likely attempt to find a driver and fail, showing an "Unknown Device" in the Device Manager. ⚙️ Step 3: Manual Installation via Device Manager
Windows often fails to "auto-detect" these industrial drivers, so you must point it to the folder manually. Right-click the Start button and select Device Manager "Other Devices" "Ports (COM & LPT)" Right-click the device (often labeled "Xinje PLC" "USB Serial Port" ) and select Update Driver "Browse my computer for driver software" and navigate to the USB_Driver folder mentioned in Step 1.
. Windows will install the driver. You may see a security warning; select "Install this driver software anyway" ✅ Step 4: Verify the Connection Once installed, the device should appear under Ports (COM & LPT) as "USB Serial Port (COMx)" or under Universal Serial Bus controllers Communication Settings
as the connection type (or select the specific COM port assigned).
. If it says "Connection Successful," you are ready to upload or download code. 💡 Troubleshooting Tips Driver Signature Error:
If Windows 10/11 blocks the install, you may need to temporarily Disable Driver Signature Enforcement in the Advanced Startup settings. Cable Check:
If no device appears in Device Manager at all, try a different USB port or cable; industrial environments are tough on hardware. Software Version:
Ensure your software version matches your PLC series (XC series uses XDPPro; XD/XL series uses XDPro). If you'd like to dive deeper, I can help you with: Finding the latest download link for XDPPro/XDPro. Step-by-step instructions for Disabling Driver Signature Enforcement A guide on uploading your first program once the driver is fixed. Which of these would be most helpful for your project?
XINJE PLCs do not use a standard CDC (Communications Device Class) USB profile like a mouse or keyboard. Instead, they often use a proprietary interface or rely on older chipset drivers (often from Silicon Labs or a generic JTAG interface). When you plug a XINJE XC or XD series PLC into a Windows 10 or 11 PC, the operating system sees a new device but does not have the appropriate .inf (Setup Information) and .sys (Driver System) files in its native library.
Win + X → Device Manager.Win + X → Device Manager.