Zkteco Ua300 | Factory Reset
To perform a factory reset on a ZKTeco UA300 biometric device, you can use the internal menu if you have administrator access, or utilize "Super Passwords" and hardware tamper switches if you are locked out. Resetting returns the device to its default state, which often includes clearing user data and reverting the IP address to 192.168.1.201. Method 1: Standard Reset via Device Menu
If you have admin access or the device is not locked, follow these steps to restore factory settings: Turn on the ZKTeco UA300
Press and hold the M/OK button for a few seconds to enter the menu. Navigate to Settings (or System). Select Restore Factory Settings (or "Initialize").
Confirm the action. The device will reboot with default configurations. Method 2: Reset Admin Privileges (If Locked Out)
If you cannot enter the menu because of a forgotten admin password, you can use a time-based "Super Password":
Check the Time: Note the exact time displayed on the device screen (e.g., 14:20). Generate a Super Password:
Option A: Use a specialized ZKTeco Password Reset Tool on a PC. Enter the device's time to generate a one-minute temporary password. zkteco ua300 factory reset
Option B (Manual Calculation): Subtract the time from 9999 (e.g., ) and multiply the result by itself ( ). The resulting number is the super password. Unlock the Device: Press Menu on the device. When prompted for an ID, enter 8888 and press OK. Enter the Super Password when prompted for the password.
Clear Admin: Once inside the menu, go to System Options > Advanced Options > Clear Admin Privileges to remove the lock. Method 3: Hard Reset via Tamper Switch
For models with a physical tamper switch (located on the back of the device), you can force a reset: Restart the device.
Wait for about 30–60 seconds after it boots until you hear a short beep.
Press the Tamper Switch three times quickly (within 30 seconds of the beep).
This may reset the admin password to the default, which is typically 12345. Method 4: Reset via Management Software To perform a factory reset on a ZKTeco
If the device is connected to your network, you can reset it using ZKTeco Software like ZKTime 5.0: Connect the device to your PC via a network cable. Open the software and go to Device > Connect.
Navigate to Device Management > AC Manage > Advanced Function.
Select Clear Admin to remove passwords or Initialize to wipe all data and settings.
Warning: Performing an "Initialization" through the software or menu will permanently delete all registered fingerprints and attendance logs. Ensure you have backups if this data is required. ZKTeco Admin Password Reset
Part 3: Method 1 – Soft Reset via Menu (If You Know the Admin Password)
If you currently have Supervisor or Admin access, do not open the device. Use the on-screen menu:
- Power on the UA300.
- Press
Menuon the keypad. - Enter Admin Password (Default:
1234or8888or0000). - Use the down arrow to navigate to
System>Advanced. - Scroll to
Restore Factory SettingsorReset. - The device will ask: “Delete all data?” Select OK.
- The UA300 will reboot. You will see the default “ZKTeco” logo.
Aftermath: The device is now at default settings: IP 192.168.1.201, Port 4370, Password 1234. Power on the UA300
Q1: Will a factory reset remove the firmware version?
No. A factory reset only erases user data, logs, and settings. The firmware (operating system) remains the same version.
Q3: Does the device need to be connected to a PC for reset?
No. In 99% of cases, you can reset directly from the touch screen or boot menu.
What if the Engineering Menu doesn’t appear?
Try different tapping rhythms: double-tap rapidly, or tap continuously from the moment power is applied. Some firmware versions require you to press the physical power button (if equipped) while tapping the screen.
8. Conclusion
The ZKTeco UA300 factory reset is a powerful recovery tool but results in complete data loss of users and logs. The menu method is safest when admin access exists. The hardware jumper method is the only way to bypass a lost admin password. Always verify the PCB revision and jumper location before shorting to avoid damage.
Tools You May Need:
- Philips Head Screwdriver (to open the back casing for hard reset).
- A paperclip or jumper wire.
- Ethernet cable and a laptop (for software-based reset).
- The ZKAccess 3.5 or Attendance Enterprise software.
Post‑reset checklist
- Re-enroll admin user(s) and test login.
- Set date/time and network settings (IP/DNS).
- Restore or re-import backed-up user templates and time logs if available.
- Reconfigure access control settings, door relay, Wiegand settings, and log export schedule.
- Test reader, lock control, exit button, and any integrated sensors.
How to Perform the Factory Reset (Review Context)
Based on user manuals and technical support forums, the standard method involves the device's physical buttons (since the UA300 has no touchscreen GUI option for this):
- Power Off the device.
- Press and hold the OK button (or sometimes the Back/Esc button depending on firmware revision).
- While holding the button, power on the device.
- Keep holding until you see a menu or a prompt mentioning "Restore Defaults" or "Factory Reset" .
- Navigate using the arrow keys to confirm (usually select "Yes").
- The device will reboot, returning to default IP (
192.168.1.201), default communication credentials (often no password or12345), and zero users.